Dust/Chip Extraction

Do not perform work without taking dust-reducing measures. Using a suitable dust extraction attachment will reduce exposure to harmful dust. Provide good ventilation at the workplace. Always use suitable breathing protection. Use a dust extraction system that is suitable for the material wherever possible. The regulations on the materials being machined that apply in the country of use must be observed.

Requirements for the Dust Extractor

Recommended hose nominal diameter

mm

35

Required vacuum pressureA)

mbar
hPa

≥ 230
≥ 230

Required flow rateA)

l/s
m³/h

≥ 36
≥ 129.6

Recommended filter efficiency

Dust class MB)

A)

Power value at the power tool’s dust extractor connection

B)

According to IEC/EN 60335-2-69

Refer to the dust extractor’s instructions. If there is reduced suction power, stop working and eliminate the cause.

Fitting the dust extraction adapter (see figure E)

Push the dust extraction adapter (25) onto the chip ejector (14) until it clicks into place. Then secure the dust extraction adapter (25) in place with the screw (26).

A dust extraction hose with a diameter of 35 mm can be connected to the dust extraction adapter (25).

To ensure optimum extraction, the dust extraction adapter (25) must be cleaned regularly.